Electrical arc flash protection is one of the most important safety controls in modern mining. If you’re looking for the best arc guard power center options for mines, the short answer is this: choose arc-resistant, ANSI/IEEE-tested power centers designed specifically for mining conditions, with reinforced enclosures, controlled venting, and configurable layouts — like those engineered and supplied by Becker Mining USA across the United States. These systems are built to reduce arc flash risk, protect workers, and keep operations running.
Mining sites deal with high fault currents, tight spaces, dust, vibration, and moisture. Standard switchgear is often not enough. Purpose-built arc-resistant power centers are now considered best practice for both underground and surface operations.
Key Takeaways
- Arc guard power center systems are built to contain and redirect arc flash energy
- Arc-resistant designs improve miner safety and reduce injury risk
- ANSI/IEEE C37.20.7 testing is a critical selection standard
- Becker Mining USA provides mining-specific configurations and retrofits
- Proper power center selection reduces downtime and equipment loss
The Mining Safety Challenge: Arc Flash Hazards
Arc flash events are rare — but when they happen, the impact is severe. An arc flash occurs when electrical current leaves its intended path and travels through air between conductors or to ground. In milliseconds, temperatures can exceed 35,000°F, with explosive pressure and molten metal spray.
Mining environments increase the probability and severity of these faults due to:
- Moisture and water intrusion
- Conductive dust and debris
- Equipment vibration
- Confined electrical rooms
- Continuous heavy loads
- Frequent cable handling
Traditional circuit protection reacts quickly, but not always fast enough to prevent damage from an internal arc. That gap is exactly what an arc guard power center is designed to address.
Becker Mining USA focuses on mining-duty electrical distribution systems across the USA, with equipment engineered specifically for these hazard profiles — not general industrial assumptions.

GET IN TOUCH
In a hurry? Call us at 276-285-3841
What Is an Arc Guard Power Center?
An arc guard power center is an arc-resistant electrical distribution assembly built to contain, channel, and withstand the pressure and heat of an internal arcing fault. It goes beyond standard bolted-fault ratings.
Key technical characteristics include:
- Reinforced steel enclosures
- Pressure-managed construction
- Directed arc gas venting paths
- Tested arc resistance performance
- Mining-duty mechanical design
Becker Mining USA units are tested to ANSI/IEEE C37.20.7 arc resistance standards, which evaluate how equipment behaves under real arc fault conditions — not just theoretical short circuits.
In practical terms, that means if an internal arc occurs, the enclosure is designed to:
- Stay structurally intact
- Prevent door blow-open events
- Direct hot gases away from operators
- Limit external flame release
That difference is critical for worker survival and incident containment.
Why Mines Choose Arc-Resistant Power Centers
Mining operators don’t adopt arc-resistant systems for marketing reasons — they adopt them because incident reports and field experience show the consequences of arc flash failures.
Here’s what drives adoption across U.S. mining operations.
Worker Protection at the Equipment Face
Arc-resistant construction protects personnel who are:
- Reading meters
- Operating disconnects
- Resetting breakers
- Performing diagnostics
Instead of relying only on PPE and procedures, the equipment itself becomes part of the safety barrier.
Reduced Blast Damage
Internal arcs can destroy conventional gear. Arc-resistant power centers help localize the damage area, which often means:
- Fewer destroyed compartments
- Lower replacement cost
- Faster return to service
Better Compliance Position
U.S. mining operations must meet strict MSHA electrical safety expectations. Using arc-tested power distribution equipment supports:
- Documented safety engineering controls
- Stronger audit posture
- Reduced liability exposure
Operational Stability
Unplanned electrical failures are expensive. Mine's that upgrade to arc guard power center systems often report:
- Fewer catastrophic failures
- Shorter outage duration
- Improved maintenance planning
Core Features of Becker Mining USA Arc Guard Systems
Becker Mining USA supplies mining-specific electrical infrastructure — not repurposed commercial switchgear. Their arc guard power center designs reflect field realities from underground coal to hard rock and aggregate sites.
Key design features typically include:
- Arc-resistant enclosure construction
- Compartmentalized internal sections
- Controlled pressure vent routing
- Heavy-duty bus systems
- Mining-grade cable interfaces
- Integrated protection relays
- Custom feeder configurations
These are not one-size-fits-all assemblies. They are engineered around actual load profiles and site layouts.

GET IN TOUCH
In a hurry? Call us at 276-285-3841
Best Arc Guard Power Center Options in Practice
Not every mine needs the same configuration. The “best” option depends on voltage class, distribution architecture, and physical constraints. In U.S. mining applications, three main categories are common.
Standard Arc-Resistant Power Centers
Best for:
- New installations
- Typical underground sections
- Surface distribution hubs
Typical characteristics:
- Tested arc-resistant housing
- Standard feeder layouts
- Integrated protection packages
- Proven mechanical platform
These provide strong baseline protection without complex customization.
Custom Engineered Configurations
Best for:
- Large mines
- Mixed load environments
- Complex distribution networks
Customization may include:
- Special feeder counts
- Unique breaker selections
- Integrated motor control
- Site-specific control logic
- Remote monitoring options
Becker Mining USA regularly engineers custom builds for U.S. mine operators who need tight integration with existing infrastructure.
Retrofit and Upgrade Solutions
Best for:
- Legacy installations
- Budget-constrained upgrades
- Phased safety improvement plans
Retrofit paths can include:
- Arc-resistant compartment upgrades
- Protection relay modernization
- Enclosure reinforcement
- Venting improvements
This approach improves safety without full system replacement — often a practical step for operating mines.
Selection Criteria That Actually Matter
When evaluating arc guard power center options, decision makers should focus on measurable engineering factors — not just brochures.
Prioritize:
- Verified arc resistance testing
- ANSI/IEEE compliance documentation
- Mining-specific mechanical ratings
- Serviceability of compartments
- Availability of U.S. technical support
- Field service network coverage
- Spare parts availability
Becker Mining USA’s U.S. presence matters here. Domestic engineering support and parts logistics reduce downtime when issues arise.
Real-World Impact on Mining Operations
Across multiple U.S. sites, arc-resistant power centers have changed how electrical risk is managed. Safety managers often report a shift from reactive controls to engineered prevention.
Observed outcomes commonly include:
- Lower severe incident probability
- Reduced arc flash boundary exposure
- Better worker confidence near the equipment
- More predictable maintenance cycles
One site safety lead described it simply: equipment design removed part of the risk equation before PPE was even considered. That’s the right order of controls.
Choosing the Right Arc Guard Power Center
Selecting the right arc guard power center is not just an equipment decision — it’s a safety and reliability decision. The best options are arc-tested, mining-engineered, and properly matched to your distribution design. Becker Mining USA supplies arc-resistant power centers across the USA that meet recognized standards and reflect real mining operating conditions.
If your mine is reviewing electrical risk controls, upgrading to an arc-resistant power center is one of the most direct ways to reduce hazard exposure while supporting uptime. Work with experienced mining electrical specialists, review your fault scenarios, and specify tested arc-resistant assemblies — not generic gear.
Talk with Becker Mining USA to review arc guard power center configurations that match your mine’s voltage, layout, and safety requirements.
Frequently Asked Questions
What is an arc guard power center used for in mining?
It distributes electrical power while containing and redirecting energy from internal arc faults to protect workers and equipment.
Is arc-resistant the same as explosion-proof?
No. Arc-resistant equipment is designed to manage internal electrical arc faults. Explosion-proof ratings relate to external explosive atmospheres.
Are arc guard power center systems required by code?
Not always required, but often recommended to meet safety best practices and risk reduction goals in U.S. mining operations.
Can older mining power centers be upgraded to arc-resistant designs?
Yes. Many installations can be retrofitted with arc-resistant features and updated protection systems.
What standard should arc-resistant power centers meet?
ANSI/IEEE C37.20.7 is the primary arc resistance testing standard referenced for this type of equipment.
Products We Offer:
- Explosion Proof Equipment
- Transformers
- Arc Guard
- Longwall Electrical Systems
- Capacitor Trip Devices
- Electrical Equipments like capacitor banks, switch houses, junctions, and splice boxes.
Power up your productivity with Becker Mining's ground fault relays - the reliable and efficient solution for all your power distribution needs. Call us today!
GET IN TOUCH
In a hurry? Call us at 276-285-3841